Command reference / comm
CHGCTLLWS
Change Controller Description
Updates the description of a local workstation controller, including its configuration and associated devices.
Allowed environments: *ALL.
Positional parameters: 1.
Parameters
CTLD
Controller description
Enter the name of the local workstation controller description to change.
RSRCNAME
Resource name
Sets the resource name that identifies the hardware this description represents. Use the WRKHDWRSC command to determine the resource name.
Suggested / special values:
*SAME
*SAME- Keep the current setting.
ONLINE
Online at IPL
Controls whether this object is automatically varied on at initial program load (IPL).
Allowed values:
*NO, *SAME, *YES
*SAME- Keep the current setting.
*YES- The controller is automatically varied on at IPL.
*NO- The controller is not automatically varied on at IPL.
DEVWAITTMR
Device wait timer
Sets the device wait timeout value. This is used to limit the amount of time that a subsystem takes for the work station input/output to complete.
Suggested / special values:
*SAME
*SAME- Keep the current setting.
device-wait-timer- Enter a value ranging from 2 through 600 that specifies the maximum number of seconds that the subsystem waits for work station input/output to complete for all work stations attached to this controller.
AUTOCFG
Auto-configuration controller
Controls whether this controller description is the one which should have devices attached when they are automatically configured. Although there can be more than one controller description for each controller, only one description can be an automatic configuration controller.
Allowed values:
*NO, *SAME, *YES
*SAME- Keep the current setting.
*NO- This is not an automatic configuration controller.
*YES- Automatic configuration controller.
INZFILE
Initialization source file
Enter the name of a source file containing configuration initialization data. Note: The INZFILE and INZMBR parameters are required when downloading extended wireless controller configuration data to the wireless adapter as discussed at the beginning of this command description.
Suggested / special values:
*SAME
*SAME- Keep the current setting.
*NONE- Leave initialization file name unspecified.
*LIBL- Look in the thread's library list.
*CURLIB- Look in the current library, falling back to QGPL.
library-name- Enter the name of the library to be searched.
initialization-file-name- Enter the name of a source file containing the initialization data. A value of *NONE is accepted for this parameter.
Qualified parts (object, then library; write LIBRARY/OBJECT)
Part 5-01
Part 5-11
Suggested / special values:
*LIBL, *CURLIB
INZMBR
Initialization source member
Enter the name of a source file member containing configuration initialization data (for a type 266A controller only). Note: The INZFILE and INZMBR parameters are required when downloading extended wireless controller configuration data to the wireless adapter as discussed at the beginning of this command description.
Suggested / special values:
*NONE, *SAME
*SAME- Keep the current setting.
*NONE- Leave source file member unspecified.
initialization-member-name- Enter the name of a source file member containing the initialization data. A value of *NONE is accepted for this parameter.
INZPGM
Initialization program
Enter the name of a program to manage configuration initialization data. Note: For 2663 wireless adapters, it is recommended that INZPGM(QZXCINZ) be specified.
Suggested / special values:
*SAME
*SAME- Keep the current setting.
*NONE- Leave initialization program name unspecified.
*LIBL- Look in the thread's library list.
*CURLIB- Look in the current library, falling back to QGPL.
library-name- Enter the name of the library to be searched.
initialization-program-name- Enter the name of a program to manage configuration initialization data. If a program name is specified, it is called when this controller description is created.
Qualified parts (object, then library; write LIBRARY/OBJECT)
Part 7-01
Part 7-11
Suggested / special values:
*LIBL, *CURLIB
MSGQ
Message queue
Sets the message queue to which operational messages are sent.
Suggested / special values:
*SAME, *SYSOPR, *SYSVAL
*SAME- Keep the current setting.
*SYSVAL- Messages are sent to the message queue defined in the QCFGMSGQ system value.
*SYSOPR- Messages are sent to the system operator message queue (QSYS/QSYSOPR).
name (message queue)- Enter the name of the message queue to which operational messages are sent.
name (library)- Enter the name of the library where the message queue is located.
Qualified parts (object, then library; write LIBRARY/OBJECT)
Part 8-01
Part 8-11
Suggested / special values:
*LIBL, *CURLIB
TEXT
Text 'description'
Sets the text that briefly describes the object.
Suggested / special values:
*BLANK, *SAME
*SAME- Keep the current setting.
*BLANK- Leave the description blank.
character-value- Enter no more than 50 characters of text, enclosed in apostrophes.
Examples
CHGCTLLWS CTLD(MYCTLR) INZMBR(MBR3)
Changes the controller description MYCTLR so that configuration initialization data is now contained in member MBR3 of the same source file as originally specified for this controller.
Generated from os/cl/catalog/CHGCTLLWS.json and os/cl/help/CHGCTLLWS.json.