Command reference / comm
CHGDEVAPPC
Change Device Description
Updates the description of an advanced program-to-program communications device.
Allowed environments: *ALL.
Positional parameters: 1.
Parameters
DEVD
Device description
Enter the name of the device description.
ONLINE
Online at IPL
Controls whether this object is automatically varied on at initial program load (IPL).
Allowed values:
*NO, *SAME, *YES
*SAME- Keep the current setting.
*YES- This device is varied on automatically at IPL.
*NO- This device is not varied on automatically at IPL.
MODE
Mode
Sets the names of the modes that define the sessions on this device.
Suggested / special values:
*NETATR, *SAME
*SAME- Keep the current setting.
*NETATR- The remote network identifier specified in the network attributes is used.
mode-name- Enter the name of mode descriptions used by this device. The mode name cannot be CPSVCMG or SNASVCMG; these mode names are reserved for system use.
MSGQ
Message queue
Sets the message queue to which operational messages for this device are sent.
Suggested / special values:
*CTLD, *SAME, *SYSOPR
*SAME- Keep the current setting.
*CTLD- Messages are sent to the message queue defined in the attached controller. The message queue is determined when the device is varied on.
*SYSOPR- Messages are sent to the system operator message queue (QSYS/QSYSOPR).
message-queue-name- Enter the name of the message queue to which operational messages are sent.
*LIBL- All libraries in the job's library list are searched until the first match is found.
*CURLIB- Look in the current library, falling back to QGPL.
library-name- Enter the name of the library to be searched.
Qualified parts (object, then library; write LIBRARY/OBJECT)
Part 3-01
Part 3-11
Suggested / special values:
*LIBL, *CURLIB
LOCADR
Local location address
Sets the local location address for this device.
Suggested / special values:
*SAME
*SAME- Keep the current setting.
SNGSSN
Single session
Controls whether a single or multiple sessions are used with remote locations. If single sessions are used, the number of conversations must be specified.
Suggested / special values:
*NO, *SAME
*SAME- Keep the current setting.
*NO- Multiple sessions are used.
*YES- Single sessions are used.
conversations- Enter a valid value that ranges from 1 through 512 for the number of conversations.
Elements in order
Single session capable
Single session capable
Suggested / special values:
*YES
Number of conversations
Number of conversations
LCLCTLSSN
Locally controlled session
Controls whether the session is a locally controlled session.
Allowed values:
*NO, *SAME, *YES
*SAME- Keep the current setting.
*NO- The single session is remotely controlled.
*YES- The single session is locally controlled.
PREESTSSN
Pre-established session
Controls whether the session is established when the connection with the remote system is established.
Allowed values:
*NO, *SAME, *YES
*SAME- Keep the current setting.
*NO- The session is not established automatically at connection time.
*YES- The session is established automatically at connection time.
LOCPWD
Location password
Sets the password to be used to validate a connection.
Suggested / special values:
*NONE, *SAME
*SAME- Keep the current setting.
*NONE- There is no password.
location-password- Enter the password as a string of hexadecimal characters.
SECURELOC
Secure location
Select how security information is handled for program start requests received from remote systems. The value is sent to the remote system when sessions are established. It is used in determining how allocate or evoke requests should be built. The value only applies to conversations started with the SECURITY(SAME) level of security.
Allowed values:
*NO, *SAME, *VFYENCPWD, *YES
*SAME- Keep the current setting.
*NO- The remote system is not a secure location. Security validation done by the remote system is not accepted. SECURITY(SAME) conversations are treated as SECURITY(NONE). No security information will be sent with allocate or evoke requests.
*YES- The remote system is a secure location and the local system will accept security validation done by remote systems. For SECURITY(SAME) conversations, the local system allows the remote system to verify user passwords.
*VFYENCPWD- The remote system is not a secure location. For SECURITY(SAME) conversations, the remote system is not allowed to send the already verified indicator. On the remote system, user IDs and passwords are retrieved from the security manager.
TEXT
Text 'description'
Sets the text that briefly describes the object.
Suggested / special values:
*BLANK, *SAME
*SAME- Keep the current text (if any).
*BLANK- Leave the description blank.
character-value- Enter no more than 50 characters of text, enclosed in apostrophes.
Examples
CHGDEVAPPC DEVD(APPC1) SNGSSN(*NO)
Changes the device description for communication device APPC1 so it is no longer limited to single sessions.
Generated from os/cl/catalog/CHGDEVAPPC.json and os/cl/help/CHGDEVAPPC.json.