Command reference / comm

CHGDEVDSP

Change Device Description

Updates a display device description and the attributes used for sessions on that device.

Allowed environments: *ALL. Positional parameters: 1.

Parameters

DEVD Device description

Enter the name of the device description.

Type
*NAME
Required
Yes
Length
10
Case
Uppercase

PORT Port number

Sets the port number for local devices.

Type
*INT4
Required
No
Default
*SAME
Range
0 to 17
Case
Uppercase

Suggested / special values: *SAME

*SAME
Keep the current setting.
port-number
Enter the port number. Valid values range from 0 through 65535.

SWTSET Switch setting

Sets the switch setting for local twinaxial devices.

Type
*INT4
Required
No
Default
*SAME
Range
0 to 6
Case
Uppercase

Suggested / special values: *SAME

*SAME
Keep the current setting.

SHRSSNNBR Shared session number

Sets the shared session number for a twinaxial display station. This parameter is valid only for 3486 and 3487 configured device types. Note: Displays that share session addresses can be attached only to the 2661, 6050, 9146, or the 915A local work station controllers, or to the 5494 remote work station controller.

Type
*INT4
Required
No
Default
*SAME
Range
0 to 3
Case
Uppercase

Suggested / special values: 0, 1, 2, 3, *SAME

0
The shared session number is 0.
1
The shared session number is 1.
2
The shared session number is 2.
3
The shared session number is 3.
*SAME
Keep the current setting.

LOCADR Local location address

Sets the local location address for this device.

Type
*CHAR
Required
No
Default
*SAME
Length
50
Case
Uppercase

Suggested / special values: *SAME

3174
02-41.
3274
02-41.
4680
02-54.
4684
02-FE.
4701
02-FE.
4702
02-FE.
5251
00, 02-09.
5294
00-1B.
5394
00-14.
5494
00-37.
Controller
Valid Values.
SNA Host
01-FE.
FBSS
02-FE.
*SAME
Keep the current setting.

ONLINE Online at IPL

Controls whether this object is automatically varied on at initial program load (IPL).

Type
*CHAR
Required
No
Default
*SAME
Length
50
Case
Uppercase

Allowed values: *NO, *SAME, *YES

*SAME
Keep the current setting.
*YES
This device is varied on automatically at IPL.
*NO
This device is not varied on automatically at IPL.

KBDTYPE Keyboard language type

Sets the country keyboard language identifier for this display station.

Type
*CHAR
Required
No
Default
*SAME
Length
50
Case
Uppercase

Suggested / special values: *NONE, *SAME, *SYSVAL

3101
A.
3151
B.
3161
B.
3162
B.
3163
B.
3164
B.
*SYSVAL
Instructs the system to use the QKBDTYPE system value.
keyboard language-type
Enter the 3-character country identifier (used for EBCDIC and ASCII) for this display station.
Identifier
Language(Country) - ASCII Device Groups.
ALI
Albania.
ALM
Albania Euro Currency.
CLB
Arabic X/Basic - D*
CLE
Arabic X/Basic Euro Currency.
AGB
Austria/Germany - A, B.
AGE
Austria/Germany Euro Currency.
AGI
Austria/Germany Multinational - A, B.
AGM
Austria/Germany Multinational Euro Currency.
BLI
Belgium Multinational - B.
BLM
Belgium Multinational Euro Currency.
BRB
Brazilian Portuguese.
BRE
Brazilian Portuguese Euro Currency.
BGB
Bulgaria.
BGE
Bulgaria Euro Currency.
CAB
Canadian French - A, B.
CAE
Canadian French Euro Currency.
CAI
Canadian French Multinational - A, B.
CAM
Canadian French Multinational Euro Currency.
SPB
Catalan.
RCB
Chinese (Simplified)
TAB
Chinese (Traditional)
YGI
Croatia.
YGM
Croatia Euro Currency.
CYB
Cyrillic.
CSB
Czech Republic.
CSE
Czech Republic Euro Currency.
DMB
Denmark - B.
DME
Denmark Euro Currency.
DMI
Denmark Multinational - B.
DMM
Denmark Multinational Euro Currency.
ESB
Estonia.
FNB
Finland/Sweden - B.
FNE
Finland/Sweden Euro Currency.
FNI
Finland/Sweden Multinational - B.
FNM
Finland/Sweden Multinational Euro Currency.
FAB
France (Azerty) - A, B.
FAE
France (Azerty) Euro Currency.
FAI
France (Azerty) Multinational - A, B.
FAM
France (Azerty) Multinational Euro Currency.
FQB
France (Qwerty)
FQI
France (Qwerty) International.
GNB
Greek (see note)
GNE
Greek Euro Currency.
NCB
Hebrew - D*
NCE
Hebrew Euro Currency.
HIB
Hindi.
HNB
Hungary.
HNE
Hungary Euro Currency.
ICB
Iceland.
ICE
Iceland Euro Currency.
ICI
Iceland Multinational.
ICM
Iceland Multinational Euro Currency.
INB
International.
INI
International Multinational.
IRB
Iran (Farsi)
ITB
Italy - A, B.
ITE
Italy Euro Currency.
ITI
Italy Multinational - A, B.
ITM
Italy Multinational Euro Currency.
JEB
Japan English.
JEI
Japan English Multinational.
JKB
Japan Kanji.
JPB
Japan Latin Extended.
JPE
Japan Latin Extended Euro Currency.
JUB
Japan U.S. Basic.
KAB
Japan Katakana.
KOB
Korea.
LAB
Lao People's Democratic Republic.
LAE
Lao People's Democratic Republic Euro Currency.
ROB
Latin-2/ROECE.
ROE
Latin-2/ROECE Euro Currency.
LVB
Latvia.
LTB
Lithuania.
MKB
FYR Macedonia (Former Yugoslav Republic)
MKE
FYR Macedonia Euro Currency.
NEB
Netherlands.
NEE
Netherlands Euro Currency.
NEI
Netherlands Multinational.
NEM
Netherlands Multinational Euro Currency.
NWB
Norway - B.
NWE
Norway Euro Currency.
NWI
Norway Multinational - B.
NWM
Norway Multinational Euro Currency.
PLB
Poland.
PLE
Poland Euro Currency.
PRB
Portugal - B.
PRE
Portugal Euro Currency.
PRI
Portugal Multinational - B.
PRM
Portugal Multinational Euro Currency.
RMB
Romania.
RME
Romania Euro Currency.
RUB
Russia.
RUE
Russia Euro Currency.
SQB
Serbia (Cyrillic)
SQE
Serbia (Cyrillic) Euro Currency.
YGI (2)
Serbia (Latin)
YGM (2)
Serbia (Latin) Euro Currency.
SKB
Slovakia.
SKE
Slovakia Euro Currency.
YGI (3)
Slovenia.
YGM (3)
Slovenia Euro Currency.
SPB (2)
Spain - B.
SPE
Spain Euro Currency.
SPI
Spain Multinational - B.
SPM
Spain Multinational Euro Currency.
SSB
Spanish Speaking - B.
SSE
Spanish Speaking Euro Currency.
SSI
Spanish Speaking Multinational - B.
SSM
Spanish Speaking Multinational Euro Currency.
SWB
Sweden - B.
SWE
Sweden Euro Currency.
SWI
Sweden Multinational - B.
SWM
Sweden Multinational Euro Currency.
SFI
Switzerland/France Multinational - B.
SFM
Switzerland/France Multinational Euro Currency.
SGI
Switzerland/Germany Multinational - B.
THB
Thailand.
THE
Thailand Euro Currency.
TKB
Turkey (Qwerty)
TKE
Turkey (Qwerty) Euro Currency.
TRB
Turkey (F)
TRE
Turkey (F) Euro Currency.
UAB
Ukraine.
UAE
Ukraine Euro Currency.
UKB
United Kingdom - A, B.
UKE
United Kingdom Euro Currency.
UKI
United Kingdom Multinational - A, B.
UKM
United Kingdom Multinational Euro Currency.
USB
United States/Canada - A, B, C.
USE
United States/Canada Euro Currency.
USI
United States/Canada Multinational - A, B, C.
USM
United States/Canada Multinational Euro Currency.
PKB
Urdu.
PKE
Urdu Euro Currency.
VNB
Vietnam.
VNE
Vietnam Euro Currency.
YGI (4)
Languages of the former Yugoslavia.
YGM (4)
Languages of the former Yugoslavia Euro Currency.
Display
ASCII Device Group.
Display (2)
Description.
D220
Data General Dasher D220.
T910
TeleVideo 910.
T925
TeleVideo 925.
T955
TeleVideo 955.
V100
DEC VT-100.
V220
DEC VT-220 (supports ASCII Device Group D and C)
W30
Wyse WY30.
W50
Wyse WY50.
W60
Wyse WY60.
*SAME
Keep the current setting.
*NONE
No country keyboard language identifier is set for this display station. This is only valid for displays where the keyboard type is not required.

DROP Drop line at signoff

Specifies, for remote display stations, whether the line is disconnected by the system when all devices on the line are no longer in use.

Type
*CHAR
Required
No
Default
*SAME
Length
50
Case
Uppercase

Allowed values: *NO, *SAME, *YES

*SAME
Keep the current setting.
*YES
The switched line to the controller to which this device is attached is disconnected when this device and all other attached devices are no longer in use.
*NO
The switched line is not disconnected from the controller when all of its attached devices are no longer in use.

CHRID Character identifier

Sets the character identifier (graphic character set and code page) that a work station display device supports.

Type
*ELEM
Required
No
Default
*SAME
Case
Uppercase

Suggested / special values: *KBDTYPE, *SAME, *SYSVAL

*SAME
Keep the current setting.
*KBDTYPE
The system determines the graphic character set and code page value that corresponds to the country keyboard language identifier value specified for the Keyboard language type (KBDTYPE) parameter.
*SYSVAL
The system determines the graphic character set and code page values for the command parameters from the QCHRID system value.
graphic-character-set code-page
Enter the graphic character set and code page values that match the attributes of this display device. The graphic character set and code page values must be numbers in the range of 1 through 32767.
Elements in order

Graphic character set Graphic character set

Type
*INT4
Required
No
Range
1 to 32767
Case
Uppercase

Code page Code page

Type
*INT4
Required
No
Range
1 to 32767
Case
Uppercase

ALWBLN Allow blinking cursor

Controls whether the (program controlled) blinking cursor is suppressed. Note: The value specified for this parameter can be overridden by display stations that have a keyboard setup capability that allows the blinking cursor attribute to be changed.

Type
*CHAR
Required
No
Default
*SAME
Length
50
Case
Uppercase

Allowed values: *NO, *SAME, *YES

*SAME
Keep the current setting.
*YES
Allows the cursor to blink for the 3179, 3180, 3196, 3197, 3476, 3477, 3486, 3487, 5251, 5291, and 5292 display devices.
*NO
The blinking cursor is suppressed.

AUXDEV Auxiliary device

Sets the device type and address of an additional device (if any) that is attached to the IEEE-488 port on the 5292 Model 2 device. Up to 31 plotters can be attached to the same IEEE-488 AUXDEV port on the 5292 Model 2, but at different IEEE-488 addresses.

Type
*ELEM
Required
No
Default
*SAME
Case
Uppercase

Suggested / special values: *NONE, *SAME

*SAME
Keep the current setting.
*NONE
There are no auxiliary devices.
Elements in order

Auxiliary device type Auxiliary device type

Type
*CHAR
Required
No
Length
50
Case
Uppercase

Auxiliary device address Auxiliary device address

Type
*INT4
Required
No
Range
1 to 31
Case
Uppercase

PRTDEV Print device

Enter the name of the default printer device for this workstation. If the printer file being used to create the output specifies to spool the file, the spooled file is placed on the device's output queue, which is named the same as the device. Note: This assumes the defaults are specified on the OUTQ parameter for the printer file, job description, user profile and workstation.

Type
*NAME
Required
No
Default
*SAME
Length
10
Case
Uppercase

Suggested / special values: *SAME, *SYSVAL

*SAME
Keep the current setting.
*SYSVAL
The default system printer specified in the system value QPRTDEV is used.
printer-device-name
Enter the name of a printer that is used to print the output.

OUTQ Output queue

Sets the name and library of the output queue that is used by the user. The output queue must already exist.

Type
*QUAL
Required
No
Default
*SAME
Case
Uppercase

Suggested / special values: *DEV, *SAME

*SAME
Keep the current setting.
*DEV
The output queue associated with the printer specified on the DEV parameter of the printer file is used.
output-queue-name
Enter the name of the output queue.
*LIBL
Look in the thread's library list.
*CURLIB
The current library is used to locate the output queue. If no current library entry exists in the library list, QGPL is used.
library-name
Enter the name of the library where the output queue is located.
Qualified parts (object, then library; write LIBRARY/OBJECT)

Part 12-01

Type
*NAME
Required
No
Length
10
Case
Uppercase

Part 12-11

Type
*NAME
Required
No
Length
10
Case
Uppercase

Suggested / special values: *LIBL, *CURLIB

PRINTER Printer

Specifies, for a remote display station, the device name of the printer associated with the display device. The device description of the work station printer named in this parameter must have already been created and must currently exist on the system. Both the printer and the display device must be attached to the same controller.

Type
*NAME
Required
No
Default
*SAME
Length
10
Case
Uppercase

Suggested / special values: *NONE, *SAME

*SAME
Keep the current setting.
*NONE
No printer is associated with this display station.

PRTFILE Printer file

Sets an alternative printer device file to be used for processing the Print key on this display station.

Type
*QUAL
Required
No
Default
*SAME
Case
Uppercase

Suggested / special values: *SAME

*SAME
Keep the current setting.
*LIBL
Look in the thread's library list.
*CURLIB
Look in the current library, falling back to QGPL.
library-name
Enter the library where the object is located.
Qualified parts (object, then library; write LIBRARY/OBJECT)

Part 14-01

Type
*NAME
Required
No
Length
10
Case
Uppercase

Part 14-11

Type
*NAME
Required
No
Length
10
Case
Uppercase

Suggested / special values: *LIBL, *CURLIB

ACTTMR Activation timer

Sets the amount of time (in seconds) to wait for the device to respond to the activation request from the host IBM i. If the device does not respond within this time, it is considered not available. Note: This parameter is valid only on switched lines and when *SNPT is specified for the DEVCLS parameter.

Type
*INT4
Required
No
Default
*SAME
Range
1 to 2550
Case
Uppercase

Suggested / special values: *SAME

*SAME
Keep the current setting.
activate-time
Enter a number ranging from 1 through 2550 indicating the number of seconds before the device is considered not available.

INACTTMR Inactivity timer

Sets an inactivity timer (time-out) value for display devices. This parameter also specifies what happens when the time-out value is exceeded, dependent on other attributes of the device:

Type
*INT4
Required
No
Default
*SAME
Range
1 to 30
Case
Uppercase

Suggested / special values: *ATTACH, *NOMAX, *SAME, *SEC15, *SEC30

*SAME
Keep the current setting.
*ATTACH
This value varies by the value specified on the Physical attachment (ATTACH) parameter and certain values on the Application type (APPTYPE) parameter and Device class (DEVCLS) parameter.
*NOMAX
No maximum inactivity time is tracked (no inactivity timer is to be enforced).
*SEC15
A 15-second time-out period is used.
*SEC30
A 30-second time-out period is used.
inactivity-timer
Sets a time-out value in minutes.

SNPTDEV SNA pass-through device desc

Enter the name of the associated SNA pass-through device that is attached to a host or advanced program-to-program communications (APPC) controller.

Type
*NAME
Required
No
Default
*SAME
Length
10
Case
Uppercase

Suggested / special values: *NONE, *SAME

*SAME
Keep the current setting.
*NONE
Leave name unspecified.
associated-device-name
Enter the name of a device that is attached to a host or an APPC controller that is associated with this device.

SNPTGRP SNA pass-through group name

Sets the name configured for a group of host devices in a configuration list (see CRTCFGL command). This indicates that this device is associated with any one of the devices in that group which is available.

Type
*NAME
Required
No
Default
*SAME
Length
10
Case
Uppercase

Suggested / special values: *NONE, *SAME

*SAME
Keep the current setting.
*NONE
Leave name unspecified.
group-name
Enter the name configured for a group of host devices that must be associated with this device.

LOGON Host signon/logon command

Sets the sign-on (logon) text. This parameter is allowed when DEVCLS(*SNPT) or APPTYPE(*NRF) is specified. APPTYPE(*NRF) specifies the logon string that is sent to the host system when a request is made to establish a session. DEVCLS(*SNPT) specifies the sign-on (logon) text that is sent to the host system after starting SNA pass-through support.

Type
*CHAR
Required
No
Default
*SAME
Length
50
Case
Uppercase

Suggested / special values: *NONE, *SAME

*SAME
Keep the current setting.
*NONE
No text is sent to the host system.
host-logon-command
Enter text that is sent to the host system. The text must be enclosed in apostrophes if it contains blanks or other special characters.

LINESPEED Line speed

Sets the line speed in bits per second (bps).

Type
*CHAR
Required
No
Default
*SAME
Length
50
Case
Uppercase

Suggested / special values: *SAME, *TYPE

*SAME
Keep the current setting.
*TYPE
The system uses the suggested setting for this device type.
line-speed
Enter the line speed. Valid values are: 150, 300, 600, 1200, 1800, 2400, 3600, 4800, 7200, 9600, 19200, or 38400.

WORDLEN Word length

Specifies, for ASCII devices, the word length (bits per character) used to communicate over the attachment between the ASCII work station controller and the device. For modem and Post Telephone and Telegraph (PTT) attachments, the word length must be the same as the word length selected for the modem.

Type
*INT4
Required
No
Default
*SAME
Range
7 to 8
Case
Uppercase

Suggested / special values: 7, 8, *SAME, *TYPE

7
Sets 7-bit word lengths.
8
Sets 8-bit word lengths.
*SAME
Keep the current setting.
*TYPE
The system uses the suggested setting for this device type. *TYPE selects 8 bit word lengths for all display stations except the 3101 and D220 display stations which select 7 bit word lengths.

PARITY Type of parity

Specifies, for ASCII devices, the type of parity used to communicate over the attachment between the ASCII work station controller and the device. For modem and Post Telephone and Telegraph (PTT) attachments, the type of parity must be the same as the type of parity selected for the modem.

Type
*CHAR
Required
No
Default
*SAME
Length
50
Case
Uppercase

Allowed values: *EVEN, *MARK, *NONE, *ODD, *SAME, *SPACE, *TYPE

*SAME
Keep the current setting.
*TYPE
The system uses the suggested setting for this device type.
*EVEN
Sets Even parity.
*ODD
Sets Odd parity.
*NONE
Sets that no parity bit is used.
*MARK
Sets Mark parity (1 is used for the parity).
*SPACE
Sets Space parity (0 is used for the parity).

STOPBITS Stop bits

Specifies, for ASCII devices, the number of stop bits used to communicate over the attachment between the ASCII work station controller and the device. For modem and Post Telephone and Telegraph (PTT) attachments, the number of stop bits must be the same as the number of stop bits selected for the modem.

Type
*INT4
Required
No
Default
*SAME
Range
1 to 2
Case
Uppercase

Suggested / special values: 1, 2, *SAME, *TYPE

1
Sets 1 stop bit.
2
Sets 2 stop bits.
*SAME
Keep the current setting.
*TYPE
The system uses the suggested setting for this device type.

MAXOUT Maximum outstanding frames

Sets the maximum number of frames that are sent sequentially to a remote system before the remote system (the 5150 work station) must respond. The maximum number of frames must be between 1 and 7.

Type
*INT4
Required
No
Default
*SAME
Range
1 to 7
Case
Uppercase

Suggested / special values: *SAME

*SAME
Keep the current setting.
maximum-outstanding-frames
Enter a value from 1 to 7 for the number of frames.

IDLTMR Idle timer

Sets the time (in 0.1 second intervals) that the system waits for a response. If no response is received in the specified amount of time, then error recovery procedures are started.

Type
*INT4
Required
No
Default
*SAME
Range
10 to 250
Case
Uppercase

Suggested / special values: *SAME

*SAME
Keep the current setting.
idle-timer
Enter a value from 10 to 250 in 0.1 second intervals.

NRMPOLLTMR NRM poll timer

Sets the interval (in 0.1 second intervals) for polling this device when it is in normal response mode (NRM). This parameter is valid only if 5150 is specified for the Device type (TYPE) parameter and A1 is specified for the Device model (MODEL) parameter or if ASCII port sharing is being used.

Type
*INT4
Required
No
Default
*SAME
Range
2 to 100
Case
Uppercase

Suggested / special values: *SAME

*SAME
Keep the current setting.
NRM-poll-timer
Enter a value from 2 to 100 in 0.1 second intervals.

FRAMERTY Frame retry

Sets the number of retries for an unanswered command frame or unacknowledged information frame. This parameter is valid only if 5150 is specified for the Device type (TYPE) parameter and A1 is specified for the Device model (MODEL) parameter or if ASCII port sharing is being used.

Type
*INT4
Required
No
Default
*SAME
Range
5 to 64
Case
Uppercase

Suggested / special values: *SAME

*SAME
Keep the current setting.
frame-retry
Enter a value from 5 to 64 for the number of retries.

RMTLOCNAME Remote location

Sets the remote location name of the system with which this object communicates. Note: This parameter is required for APPTYPE(*APPINIT) devices.

Type
*CHAR
Required
No
Default
*SAME
Length
50
Case
Uppercase

Suggested / special values: *SAME

*SAME
Keep the current setting.

LCLLOCNAME Local location

Sets the local location name. When this parameter is specified with APPTYPE(*CTLSSN) or APPTYPE(*APPINIT), the remote location name is the name of the independent logical unit (LU) in the network control program (NCP).

Type
*CHAR
Required
No
Default
*SAME
Length
50
Case
Uppercase

Suggested / special values: *NETATR, *SAME

*SAME
Keep the current setting.
*NETATR
The LCLLOCNAME value specified in the system network attributes is used.
local-location-name
Enter the local location name.

RMTNETID Remote network identifier

Enter the name of the remote network identifier (ID). This parameter can be specified for APPTYPE(*APPINIT) devices.

Type
*CHAR
Required
No
Default
*SAME
Length
50
Case
Uppercase

Suggested / special values: *NETATR, *NONE, *SAME

*SAME
Keep the current setting.
*NETATR
The remote network identifier specified in the network attributes is used.
*NONE
No remote network identifier (ID) is used.
remote-network-ID
Enter the ID of the remote network.

IGCFEAT DBCS feature

Select which double-byte character set (DBCS) table is used in DBCS feature code format expressing device features and the last code point value. The table at the end of this parameter description shows valid device features and last code point values for DBCS-capable devices. Note: This parameter is valid for DBCS-capable devices only.

Type
*ELEM
Required
No
Default
*SAME
Case
Uppercase

Suggested / special values: *SAME

*SAME
Keep the current setting.
device-features
Enter the device character resolution, language, and relative buffer size device features using the format SSSSLR, where:
SSSS =
The resolution (number of matrix points used to create) of the character. For example, 2424 would be 24 matrix points of height and 24 matrix points of width available to formulate the character.
L =
The language code. The 4 language codes currently supported are: J = Japanese K = Korean C = Traditional Chinese S = Simplified Chinese.
R =
The relative buffer size. The valid values are: 0, 1, 2, and 4.
last-code-point
Enter the 4-digit code point of the last double-byte character. This value can be blank.
Elements in order

Device features Device features

Type
*CHAR
Required
No
Length
50
Case
Uppercase

Last code point Last code point

Type
*CHAR
Required
No
Length
50
Case
Uppercase

TEXT Text 'description'

Sets the text that briefly describes the object.

Type
*CHAR
Required
No
Default
*SAME
Length
50
Case
Uppercase

Suggested / special values: *BLANK, *SAME

*SAME
Keep the current text (if any).
*BLANK
Leave the description blank.
character-value
Enter no more than 50 characters of text, enclosed in apostrophes.

WSCST Workstation customizing object

Enter the library-qualified name of a work station customizing object.

Type
*QUAL
Required
No
Default
*SAME
Case
Uppercase

Suggested / special values: *NONE, *SAME

*SAME
Keep the current setting.
*NONE
Leave work station customizing object unspecified.
work-station-customizing-object
Enter the work station customizing object.
*LIBL
Look in the thread's library list.
*CURLIB
Look in the current library, falling back to QGPL.
library-name
Enter the library where the object is located.
Qualified parts (object, then library; write LIBRARY/OBJECT)

Part 33-01

Type
*NAME
Required
No
Length
10
Case
Uppercase

Part 33-11

Type
*NAME
Required
No
Length
10
Case
Uppercase

Suggested / special values: *LIBL, *CURLIB

Examples

CHGDEVDSP DEVD(DSP4) PORT(1) SWTSET(5)

Moves display station DSP4 to port 1 and changes its address to 5. No other device can exist at this location on the same controller.

IBM command documentation