Command reference / db

CHGJRN

Change Journal

The Change Journal (CHGJRN) command changes the journal receiver, the journal message queue, the manage receiver attribute, the delete receiver attribute, the receiver size options, the journal state, and other attributes of the specified journal. The command allows one journal receiver to be attached to the specified journal, replacing the previously attached journal receiver. The sequence numbering of journal entries can be reset when the receiver is changed.

Allowed environments: *ALL. Positional parameters: 2.

Restrictions

Parameters

JRN Journal

Specifies the name and library of the journal for which journal receivers or operational attributes are being changed. This is a required parameter.

Type
*QUAL
Required
Yes
Case
Uppercase
*LIBL
All libraries in the library list for the current thread are searched until the first match is found.
*CURLIB
The current library for the job is searched. If no library is specified as the current library for the job, QGPL is used.
Qualified parts (object, then library; write LIBRARY/OBJECT)

Journal Journal

Type
*NAME
Required
No
Length
10
Case
Uppercase

Library Library

Type
*NAME
Required
No
Default
*LIBL
Length
10
Case
Uppercase

Suggested / special values: *LIBL, *CURLIB

JRNRCV Journal receiver

Specifies which journal receiver to attach to the specified journal. This parameter cannot be specified for remote journals.

Type
*QUAL
Required
No
List limit
2
Case
Uppercase
*SAME
The value does not change; the currently attached journal receiver remains attached.
*GEN
The journal receiver is created by the system and then attached to the specified journal, with the same attributes, owner, authorities, audit level, and library as the currently attached receiver.
Qualified parts (object, then library; write LIBRARY/OBJECT)

Journal receiver Journal receiver

Type
*NAME
Required
No
Default
*SAME
Length
10
Case
Uppercase

Suggested / special values: *SAME, *GEN

Library Library

Type
*NAME
Required
No
Default
*SAME
Length
10
Case
Uppercase

Suggested / special values: *SAME, *GEN, *LIBL, *CURLIB

SEQOPT Sequence option

Specifies whether the journal sequence number is continued from the currently attached journal receiver or reset to 1 in the newly attached journal receiver. This parameter cannot be specified for remote journals.

Type
*CHAR
Required
No
Length
6
Case
Uppercase

Allowed values: *CONT, *RESET

*CONT
The journal sequence number of the next journal entry created is one greater than the sequence number of the last journal entry in the currently attached journal receiver.
*RESET
The journal sequence number of the first journal entry in the newly attached journal receiver is reset to 1.

MSGQ Journal message queue

Specifies the qualified name of the message queue associated with the journal. A message is sent to this queue when an attached journal receiver's threshold is surpassed or when other journal events occur.

Type
*QUAL
Required
No
Default
*SAME
Case
Uppercase

Suggested / special values: *SAME

*SAME
The value does not change.
Qualified parts (object, then library; write LIBRARY/OBJECT)

Journal message queue Journal message queue

Type
*NAME
Required
No
Default
*SAME
Length
10
Case
Uppercase

Suggested / special values: *SAME

Library Library

Type
*NAME
Required
No
Default
*SAME
Length
10
Case
Uppercase

Suggested / special values: *SAME, *LIBL, *CURLIB

MNGRCV Manage receivers

Specifies how the changing of journal receivers is managed. This parameter cannot be specified for remote journals.

Type
*CHAR
Required
No
Default
*SAME
Length
7
Case
Uppercase

Allowed values: *SAME, *SYSTEM, *USER

*SAME
The value does not change.
*SYSTEM
The system manages the changing of journal receivers. When an attached journal receiver reaches its size threshold, the system detaches it and creates and attaches a new journal receiver.
*USER
The user manages the changing of journal receivers by issuing the CHGJRN command to attach a new receiver.

DLTRCV Delete receivers

Specifies whether the system deletes journal receivers when they are no longer needed. This parameter can be specified only if MNGRCV(*SYSTEM) is specified, or if the journal currently has the MNGRCV(*SYSTEM) attribute, or if the journal is a remote journal.

Type
*CHAR
Required
No
Default
*SAME
Length
6
Case
Uppercase

Allowed values: *SAME, *NO, *YES

*SAME
The value does not change.
*NO
The journal receivers are not deleted by the system.
*YES
The journal receivers are deleted by the system when they are no longer needed.

RCVSIZOPT Receiver size options

Specifies the options that affect the size of the receiver attached to the journal. This parameter cannot be specified for remote journals.

Type
*CHAR
Required
No
Default
*SAME
Length
10
List limit
3
Case
Uppercase

Allowed values: *SAME, *SYSDFT, *NONE, *RMVINTENT, *MINFIXLEN, *MAXOPT1, *MAXOPT2, *MAXOPT3

*SAME
The value does not change.
*SYSDFT
The system uses the current recommended values, currently equivalent to *MAXOPT2 and *RMVINTENT.
*NONE
No options affect the size of the journal entries. The receiver can have a maximum size of approximately 2 gigabytes.
*RMVINTENT
The size of the receiver is reduced by automatic removal of internal entries required only for IPL or ASP vary-on recovery when no longer required.
*MINFIXLEN
The size of journal entries is reduced by automatic removal of fixed-length data not required for recovery purposes.
*MAXOPT1
The receiver can have a maximum size of approximately one terabyte and a maximum sequence number of 9,999,999,999, with a maximum journal entry size of 15,761,440 bytes.
*MAXOPT2
The receiver can have a maximum size of approximately one terabyte and a maximum sequence number of 9,999,999,999, with a maximum journal entry size of 4,000,000,000 bytes.
*MAXOPT3
The receiver can have a maximum size of approximately one terabyte and a maximum sequence number of 18,446,744,073,709,551,600, with a maximum journal entry size of 4,000,000,000 bytes.

JRNSTATE Journal state

Specifies whether journal entries are allowed to be deposited into the journal. Values *ACTIVE, *INACTIVE, and *STANDBY are only valid when JRNRCV(*SAME) is specified.

Type
*CHAR
Required
No
Default
*SAME
Length
9
Case
Uppercase

Allowed values: *SAME, *ACTIVE, *INACTIVE, *STANDBY

*SAME
The value does not change.
*ACTIVE
All journal entries are allowed to be deposited into the journal. This value cannot be specified for remote journals.
*INACTIVE
This state only applies to remote journals. No entries are being received from the source system. When changed to *ACTIVE, outstanding entries will be sent.
*STANDBY
Most journal entries are not deposited into the journal. If an attempt is made to deposit an entry, there will be no errors. Using commitment control is not allowed in *STANDBY state.

TEXT Text 'description'

Specifies the text that briefly describes the journal.

Type
*CHAR
Required
No
Default
*SAME
Length
50
Case
Mixed case

Suggested / special values: *SAME, *BLANK

*SAME
The text does not change.
*BLANK
The text is replaced by blanks.

Examples

CHGJRN JRN(JRNLA) JRNRCV(RCV10) SEQOPT(*RESET)

Detaches the currently attached journal receiver from journal JRNLA. Journal receiver RCV10 is attached to JRNLA. Because SEQOPT(*RESET) is specified, the first journal entry in RCV10 has a sequence number of one.

CHGJRN JRN(JRNLA) JRNRCV(*GEN) THRESHOLD(1500000)

Detaches the currently attached journal receiver from JRNLA. A new journal receiver is created and attached with the same library, owner, authority, and auditing level as the detached receiver, and a threshold of approximately 1500000 kilobytes.

CHGJRN JRN(LIBY/JRN) JRNRCV(LIBX/RCV0001) MNGRCV(*SYSTEM) DLTRCV(*YES) RCVSIZOPT(*MAXOPT2) MNGRCVDLY(10) DLTRCVDLY(30)

Detaches the current receiver from journal JRN, attaches RCV0001 from LIBX, enables system-managed receiver changing and deletion, allows up to 1 TB receiver size with sequence numbers up to 9,999,999,999, and sets retry delays of 10 and 30 minutes.

CHGJRN JRN(QGPL/DBJRN) JRNRCV(*GEN) JRNOBJLMT(*MAX10M)

Changes journal DBJRN in QGPL to allow up to 10,000,000 objects to be journaled to it and attaches a new generated receiver.

IBM command documentation