Command reference / sys

CHGPWRSCDE

Change Power On/Off Schedule Entry

Changes the power on and power off times of the days of the week (the defaults), of one date, or the interval of the warning message that goes to every work station before the scheduled power off. Changes take effect immediately; DSPPWRSCD shows the new schedule. You must have all object (*ALLOBJ) and security administrator (*SECADM) special authority (CPF1E27). A date or a time that has passed cannot be changed (CPF1E26).

Allowed environments: *ALL. Positional parameters: 1.

Parameters

DAY Day

Specifies which day is changed: *ALL changes the default times of every day of the week, *SUN through *SAT change the default of one day, and *TODAY or a date in the job's date format change the values of that one date.

Type
*CHAR
Required
Yes
Length
10
Case
Uppercase

Suggested / special values: *ALL, *SUN, *MON, *TUE, *WED, *THU, *FRI, *SAT, *TODAY

*ALL
The default values of every day of the week are changed.
*SUN
The default values of Sunday are changed.
*MON
The default values of Monday are changed.
*TUE
The default values of Tuesday are changed.
*WED
The default values of Wednesday are changed.
*THU
The default values of Thursday are changed.
*FRI
The default values of Friday are changed.
*SAT
The default values of Saturday are changed.
*TODAY
The values of the current date are changed.

PWRONTIME Power on time

Specifies when the system powers on. Without a separator, give 4 or 6 digits (hhmm or hhmmss; hh 00-23, mm and ss 00-59). With a separator, give 5 or 8 characters using the job's time separator in apostrophes.

Type
*CHAR
Required
No
Default
*SAME
Length
8
Case
Uppercase

Suggested / special values: *SAME, *NONE, *DFT

*SAME
The power on time does not change.
*NONE
No power on time is set.
*DFT
The power on time of the date goes back to the default of its day of the week. Allowed only when DAY is *TODAY or a date.

PWROFFTIME Power off time

Specifies when the system powers off, in the same forms as PWRONTIME.

Type
*CHAR
Required
No
Default
*SAME
Length
8
Case
Uppercase

Suggested / special values: *SAME, *NONE, *DFT

*SAME
The power off time does not change.
*NONE
No power off time is set.
*DFT
The power off time of the date goes back to the default of its day of the week. Allowed only when DAY is *TODAY or a date.

DAYDESC Description

Specifies the description of the date, up to 38 characters. Allowed only when DAY is *TODAY or a date.

Type
*CHAR
Required
No
Default
*SAME
Length
38
Case
Mixed case

Suggested / special values: *SAME

*SAME
The description does not change.

MSGITV Minutes before power off to send message

Specifies how many minutes before the scheduled power off a warning message goes to all work stations, from 0 through 60. Allowed only when DAY is *ALL.

Type
*DEC
Required
No
Default
*SAME
Length
2
Range
0 to 60
Case
Uppercase

Suggested / special values: *SAME, *DFT

*SAME
The interval does not change.
*DFT
The interval is set to its default, 30 minutes.

Examples

CHGPWRSCDE DAY(*ALL) PWRONTIME(0800) PWROFFTIME(1800)

Every day of the week powers on at 08:00 and off at 18:00.

CHGPWRSCDE DAY(*SAT) PWRONTIME(*NONE) PWROFFTIME(*NONE)

Saturday has no power on or power off time.

CHGPWRSCDE DAY('11/20/26') PWROFFTIME(2000)

On 20 November 2026 the system powers off at 20:00; the power on time keeps the default of its day.

CHGPWRSCDE DAY(*ALL) MSGITV(45)

The warning message goes to all work stations 45 minutes before the scheduled power off.

IBM command documentation

Generated from os/cl/catalog/CHGPWRSCDE.json and os/cl/help/CHGPWRSCDE.json.