Command reference / comm

CRTCTLAPPC

Create Controller Description (APPC)

The Create Controller Description (APPC) (CRTCTLAPPC) command creates a controller description for an advanced program-to-program communications (APPC) controller. For more information about this command, see the Communications Configuration book, SC41-5401. Notes: Parameters no longer supported as of V5R3M0: CNNLSTOUT, CNNLSTOUTE, IDLCCNNRTY, IDLCFRMRTY, IDLCRSPTMR, IDLCWDWSIZ Parameters no longer supported as of V7R4M0: ADPTADR, APPN, ANSNBR, CNNCPNAME, CNNNBR, CNNNETID, CNNPOLLRTY, CNNPWD, DFTPKTSIZE, DFTWDWSIZE, DIALRTY, HPR, LANACCPTY, LANACKFRQ, LANACKTMR, LANCNNRTY, LANCNNTMR, LANFRMRTY, LANINACTMR, LANMAXOUT, LANRSPTMR, LANWDWSTP, LGLCHLID, LINE, LINKPCL, MDLCTL, NDMPOLLTMR, NETLVL, OUTLMT, POLLLMT, POLLPTY, PREDIALDLY, REDIALDLY, RVSCRG, SHM, SHMDSCLMT, SHMDSCTMR, SNBU, STNADR, SWTLINLST, SWTLINSLCT, TYPE, USRFCL, USRGRPID, X25ACKTMR, X25CNNRTY, X25CNNTMR, X25DLYTMR, X25FRMRTY, X25INACTMR, X25RSPTMR Link type (LINKTYPE) values no longer supported as of V7R4M0: *ANYNW, *FAX, *FR, *ILAN, *LAN, *SDLC, *TDLC, *X25.

Allowed environments: *ALL. Positional parameters: 2.

Restrictions

Parameters

CTLD Controller description

This is a required parameter. Specifies the name of the controller description.

Type
*NAME
Required
Yes
Length
10
Case
Uppercase

LINKTYPE Link type

Specifies the type of line to which this controller is attached. This is a required parameter. Note: If *HPRIP is specified, a value must be specified for the RMTINTNETA parameter. SWITCHED must remain unspecified or be *NO The MAXFRAME, RMTNETID, RMTCPNAME, EXCHID, CPSSN, NODETYPE, TMSGRPNBR, SSCPID, and ROLE parameters must not be specified SWITCHED must remain unspecified or be *NO The MAXFRAME, RMTNETID, RMTCPNAME, EXCHID, CPSSN, NODETYPE, TMSGRPNBR, SSCPID, and ROLE parameters must not be specified.

Type
*CHAR
Required
Yes
Length
50
Case
Uppercase

Allowed values: *HPRIP, *LOCAL, *OPC, *VRTAPPN

*HPRIP
This controller will allow HPR (High Performance Routing) to use the Internet as a link layer, allowing HPR data to be transported over Internet networks.
*LOCAL
This controller uses no communication lines since all communications are local. If *LOCAL is specified, the following criteria must be met: SWITCHED must remain unspecified or be *NO. The MAXFRAME, RMTNETID, RMTCPNAME, EXCHID, CPSSN, NODETYPE, TMSGRPNBR, SSCPID, and ROLE parameters must not be specified.
*OPC
This controller is attached to the optical bus (OptiConnect).
*VRTAPPN
This controller is used for APPN communications. It is not attached to any specific communications line. If *VRTAPPN is specified, the following criteria must be met: SWITCHED must remain unspecified or be *NO. The MAXFRAME, RMTNETID, RMTCPNAME, EXCHID, CPSSN, NODETYPE, TMSGRPNBR, SSCPID, and ROLE parameters must not be specified.

ONLINE Online at IPL

Specifies whether this object is automatically varied on at initial program load (IPL).

Type
*CHAR
Required
No
Default
*YES
Length
50
Case
Uppercase

Allowed values: *NO, *YES

*YES
The controller is automatically varied on at IPL.
*NO
The controller is not automatically varied on at IPL.

SWITCHED Switched connection

Specifies whether this controller is attached to a switched line.

Type
*CHAR
Required
No
Default
*NO
Length
50
Case
Uppercase

Allowed values: *NO, *YES

*NO
This controller is attached to a nonswitched line.
*YES
This controller is attached to a switched line.

RMTINTNETA Remote internet address

Specifies the TCP/IP host name or internet address to which the controller will respond. Note: This parameter is valid only when *HPRIP is specified for the Link type (LINKTYPE) parameter. An IPv4 internet address is specified in the form, nnn.nnn.nnn.nnn , where nnn is a decimal number ranging from 0 through 255. Leading zeros in each part of the dotted decimal internet address are invalid and will be removed. An IPv4 internet address is not valid if it has a value of all binary ones or zeros for the network identifier (ID) or host portion of the address. An IPv6 internet address is specified in the form x:x:x:x:x:x:x:x , where x is a hexadecimal number ranging from 0 through X'FFFF'. "::" may be used once in the IPv6 address to indicate one or more groups of 16 bits of zeros. The "::" may be used to compress leading, imbedded, or trailing zeros in the address. An IPv4-mapped IPv6 address is specified in the form ::FFFF:nnn.nnn.nnn.nnn , where nnn is decimal number ranging from 0 through 255. If the internet address is entered from the command line, the address must be enclosed in apostrophes.

Type
*CHAR
Required
No
Length
50
Case
Uppercase
host-name
This is a valid host name or a domain qualified host name associated with an internet address. A name must be between 1 and 255 characters in length.
host-internet-address
The internet address can be specified in either IPv4, IPv6 or IPv4 mapped to IPv6 form.

LCLINTNETA Local internet address

Specifies the TCP/IP interface to be used to communicate with the remote system. Note: This parameter is valid only when *HPRIP is specified for the Link type (LINKTYPE) parameter. An IPv4 internet address is specified in the form, nnn.nnn.nnn.nnn , where nnn is a decimal number ranging from 0 through 255. Leading zeros in each part of the dotted decimal internet address are invalid and will be removed. An IPv4 internet address is not valid if it has a value of all binary ones or zeros for the network identifier (ID) or host portion of the address. An IPv6 internet address is specified in the form x:x:x:x:x:x:x:x , where x is a hexadecimal number ranging from 0 through X'FFFF'. "::" may be used once in the IPv6 address to indicate one or more groups of 16 bits of zeros. The "::" may be used to compress leading, imbedded, or trailing zeros in the address. An IPv4-mapped IPv6 address is specified in the form ::FFFF:nnn.nnn.nnn.nnn , where nnn is decimal number ranging from 0 through 255. If the internet address is entered from the command line, the address must be enclosed in apostrophes.

Type
*CHAR
Required
No
Default
*SYS
Length
50
Case
Uppercase

Suggested / special values: *SYS

*SYS
The system will select the local internet address to use.
internet-address
The internet address can be specified in either IPv4, IPv6 or IPv4 mapped to IPv6 form.
Alias-name
The alias name is the same value that is specified on the ADDTCPIFC and CHGTCPIFC commands Alias name (ALIASNAME) parameter.

LDLCTMR LDLC timers

Specifies LDLC (Logical Data Link Control) timers and retry count. The LDLC retry count and LDLC retry timer are used in conjunction. The LDLC retry count and LDLC retry timer are initialized when a command or request is first transmitted over the link. If the LDLC retry timer expires before a response is received, the command or request is retransmitted, the LDLC retry count is decremented and the LDLC retry timer is restarted. If the timer expires with the LDLC retry count at zero, the link is assumed to be inoperative. The LDLC liveness timer is used to make sure that both the other endpoint of an RTP (rapid transport protocol) connection and the path between the endpoints are still operational after a period of inactivity. See High Performance Routing Architecture Reference (SV40-1018) for more information. http://publibz.boulder.ibm.com/cgi-bin/bookmgr_OS390/BOOKS/D50H6003/CCONTENTS Note: This parameter is valid only when *HPRIP is specified for the Link type (LINKTYPE) parameter.

Type
*ELEM
Required
No
Case
Uppercase
3
The LDLC retry count is 3.
10
The LDLC liveness timer is set to 10.
15
The LDLC retry timer is set to 15 seconds.
retry-count
Specify the LDLC retry counter. Valid values range from 0 to 255.
retry-timer
Specify the LDLC retry timer interval. Valid values range from 0 to 65535 seconds.
liveness-timer
Specify the LDLC liveness timer. Valid values range from 0 to 65535 seconds.
Elements in order

LDLC retry count LDLC retry count

Type
*INT4
Required
No
Default
3
Range
0 to 255
Case
Uppercase

LDLC retry timer LDLC retry timer

Type
*INT4
Required
No
Default
15
Range
0 to 65535
Case
Uppercase

LDLC liveness timer LDLC liveness timer

Type
*INT4
Required
No
Default
10
Range
0 to 65535
Case
Uppercase

LDLCLNKSPD LDLC link speed

Specifies the LDLC (Logical Data Link Control) link speed in bits per second. See High Performance Routing Architecture Reference (SV40-1018) for more information. http://publibz.boulder.ibm.com/cgi-bin/bookmgr_OS390/BOOKS/D50H6003/CCONTENTS Note: This parameter is valid only when *HPRIP is specified for the Link type (LINKTYPE) parameter. Valid values range from 1200 to 603979776000.

Type
*CHAR
Required
No
Default
*CAMPUS
Length
50
Case
Uppercase

Suggested / special values: *CAMPUS, *MAX, *MIN, *WAN

*CAMPUS
Specifies a set of default APPN link characteristics for a campus environment be used.
*WAN
Specifies a set of default APPN link characteristics for a wide-area network environment be used.
4M
The link speed is 4 million bits per second.
10M
The link speed is 10 million bits per second.
16M
The link speed is 16 million bits per second.
100M
The link speed is 100 million bits per second.
*MIN
A link speed of less than 1200 bits per second is used.
*MAX
A link speed greater than 100 million bits per second is used.
LDLC-link-speed
Specify the LDLC link speed.

LDLCTMSGRP LDLC transmission group

Specifies the LDLC (Logical Data Link Control) transmission group characteristics of Cost/connect time, Cost/byte, Security and Propagation delay. See High Performance Routing Architecture Reference (SV40-1018) for more information. http://publibz.boulder.ibm.com/cgi-bin/bookmgr_OS390/BOOKS/D50H6003/CCONTENTS Note: This parameter is valid only when *HPRIP is specified for the Link type (LINKTYPE) parameter. Cost per connect time specifies the relative cost of being connected over the link. Cost per byte specifies the relative cost of sending and receiving data over the link. Security specifies the security over the link. Propagation delay specifies the time required for a signal to travel from one end of a link to the other end.

Type
*ELEM
Required
No
Case
Uppercase
0 (Cost/connect time)
Cost per connect time is zero.
cost-connection-time
Specify the cost per connect time. Valid values range from 0 to 255.
0 (Cost/byte)
Cost per byte is zero.
cost-byte
Specify the cost per byte. Valid values range from 0 to 255.
*NONSECURE
There is no security over the link.
*PKTSWTNET (Security)
This is a packet-switched network, so the link is secure in the sense that the data does not always use the same path through the network.
*UNDGRDCBL
This is an underground cable secure conduit.
*SECURECND
This is a secured conduit but not guarded.
*GUARDCND
The link is a guarded conduit and protected against physical tapping.
*ENCRYPTED
Data flow is to be encrypted.
*MAX (Security)
This is a guarded conduit, protected against physical and radiation tapping.
*LAN
Specifies a local area network delay (less than 0.48 milliseconds).
*MIN
Specifies the minimum delay.
*TELEPHONE
Specifies a telephone network with a delay from .48 milliseconds through 49.152 milliseconds.
*PKTSWTNET (Propagation delay)
Specifies a packet-switched network with the delay from 49.152 through 245.76 milliseconds.
*SATELLITE
Specifies satellite delay (greater than 245.76 milliseconds).
*MAX (Propagation delay)
Specifies the maximum delay.
Elements in order

Cost/connect time Cost/connect time

Type
*INT4
Required
No
Default
0
Range
0 to 255
Case
Uppercase

Cost/byte Cost/byte

Type
*INT4
Required
No
Default
0
Range
0 to 255
Case
Uppercase

Security Security

Type
*CHAR
Required
No
Default
*NONSECURE
Length
50
Case
Uppercase

Suggested / special values: *NONSECURE, *PKTSWTNET, *UNDGRDCBL, *SECURECND, *GUARDCND, *ENCRYPTED, *MAX

Propagation delay Propagation delay

Type
*CHAR
Required
No
Default
*LAN
Length
50
Case
Uppercase

Suggested / special values: *LAN, *MIN, *TELEPHONE, *PKTSWTNET, *SATELLITE, *MAX

MAXFRAME Maximum frame size

Specifies the maximum frame (path information unit (PIU)) size the controller can send or receive. This value is used to calculate the request unit (RU) sizes. Since the maximum PIU size that the controller can send or receive is negotiated at exchange identifier time, the maximum PIU size used at run time may be different. This value matches the corresponding value on the host system. *HPRIP - 1461. For *HPRIP, specify a value equal to or larger than 768. Note: The numeric values listed for *LINKTYPE are valid only if TYPE(*BLANK) is specified when the controller is created.

Type
*INT4
Required
No
Default
*LINKTYPE
Range
265 to 16393
Case
Uppercase

Suggested / special values: *LINKTYPE

*LINKTYPE
For *HPRIP, the maximum frame size is 1461 when creating the controller with TYPE(*BLANK).
maximum-frame-size
Specify the frame size for the controller. The frame size that can be used depends on the type of line being used. Valid frame sizes for each line type are: For *HPRIP, specify a value equal to or larger than 768. Note: The numeric values listed for *LINKTYPE are valid only if TYPE(*BLANK) is specified when the controller is created.

RMTNETID Remote network identifier

Specifies the NAME of the remote network in which the adjacent control point resides.

Type
*CHAR
Required
No
Default
*NETATR
Length
50
Case
Uppercase

Suggested / special values: *ANY, *NETATR, *NONE

*NETATR
The LCLNETID value specified in the system network attributes is used.
*NONE
No remote network identifier (ID) is used.
*ANY
The system determines which remote network identifier is used.
remote-network-identifier
Specify the remote network identifier.

RMTCPNAME Remote control point

Specifies the control point name of the remote system.

Type
*CHAR
Required
No
Length
50
Case
Uppercase

Suggested / special values: *ANY

*ANY
The system determines the name of the remote control point used.
remote-control-point-name
Specify the remote control point NAME.

RMTSYSNAME Remote system name

Specifies the NAME of the remote system to which there is an OptiConnect bus connection. The current system NAME of the remote system can be found by using the DSPNETA command on that system. Note: This parameter is valid only when LINKTYPE(*OPC) is specified.

Type
*CHAR
Required
No
Length
50
Case
Uppercase

EXCHID Exchange identifier

Specifies the remote exchange identifier of this controller. The controller sends (exchanges) its identifier to another location when a connection is established. The 8-digit hexadecimal identifier contains 3 digits for the block number and 5 digits for the identifier of the specific controller. For the 5251, 5394, and 5294 controllers, the last five digits must begin with 000. For 5494 controllers, the last five digits are either 000nn where nn is the station address of the 5494 controller, or the last five digits of the 5494 serial number when the serial number starts with XI.

Type
*CHAR
Required
No
Length
50
Case
Uppercase

INLCNN Initial connection

Specifies the method used to establish a connection with this controller.

Type
*CHAR
Required
No
Default
*DIAL
Length
50
Case
Uppercase

Allowed values: *ANS, *DIAL

*DIAL
The system initiates outgoing calls and answers incoming calls.
*ANS
The connection is made by the IBM i system when it answers an incoming call from this controller. If a call is received from the remote controller and all necessary conditions are met, the incoming call is answered by the system.

DIALINIT Dial initiation

Specifies the method used to make the initial dial on a switched line between the system and the remote controller.

Type
*CHAR
Required
No
Default
*LINKTYPE
Length
50
Case
Uppercase

Allowed values: *DELAY, *IMMED, *LINKTYPE

*LINKTYPE
The type of dial connection initiated is specified on the LINKTYPE parameter. For all other link types, the default is to delay dialing.
*IMMED
The dial connection is initiated as soon as the controller description is varied on.
*DELAY
The dial connection is delayed until a job is initiated that requests the use of the remote controller resources.

ROLE Data link role

Specifies the data link role which the remote controller has on this connection. The primary station is the controlling station and the secondary station is the responding station. The primary station controls the data link by sending commands to the secondary station, and the secondary station responds to the commands.

Type
*CHAR
Required
No
Default
*NEG
Length
50
Case
Uppercase

Allowed values: *NEG, *PRI, *SEC

*NEG
The local system and the remote system negotiate which computer is primary.
*PRI
The remote system is the primary station on this communications line.
*SEC
The remote system is a secondary station on this communications line.

DSAP LAN DSAP

Specifies the destination service access point (DSAP). This is the logical address this system will send to when it communicates with the remote controller. This address allows the controller to properly route the data that comes from this system. The default value for the destination service access point is 04. The value must match the value specified on the source service access point (SSAP) parameter in the remote controller's configuration record. Note: The *OPC controller uses the value above for this field. The combination of RMTSYSNAME and DSAP defines a unique controller. This allows multiple controllers to exist between two systems.

Type
*CHAR
Required
No
Default
04
Length
50
Case
Uppercase
04
The destination service access point is the default 04.
destination-service-access-point
Specify a hexadecimal value ranging from 04 through 9C, in increments of 4 (for example, 04, 08, 0C, 10) to represent the destination service access point.

SSAP LAN SSAP

Specifies the source service access point (SSAP). This is the logical address the local system uses when it sends data to the remote controller. This address allows the controller to properly route the data that comes from the local system. The default value for the source service access point is 04. It must match the value assigned to the destination service access point (DSAP) in the remote controller's configuration record.

Type
*CHAR
Required
No
Default
04
Length
50
Case
Uppercase
04
The system uses the logical address of 04.
source-service-access-point
Specify a hexadecimal value ranging from 04 through 9C, in increments of 4 (for example, 04, 08, 0C, 10) to represent the source service access point.

CPSSN APPN CP session support

Specifies whether this controller supports sessions between control points.

Type
*CHAR
Required
No
Default
*YES
Length
50
Case
Uppercase

Allowed values: *NO, *YES

*YES
This controller supports sessions between control points.
*NO
This controller does not support sessions between control points.

NODETYPE Remote APPN node type

Specifies the type of APPN node which this controller represents.

Type
*CHAR
Required
No
Default
*ENDNODE
Length
50
Case
Uppercase

Allowed values: *CALC, *ENDNODE, *LENNODE, *NETNODE

*ENDNODE
This node is an end node in an APPN network.
*LENNODE
This node is a low-entry networking node in an APPN network.
*NETNODE
This node is a network node in an APPN network.
*CALC
The system determines the type of node this controller represents.

BEXROLE Branch extender role

Specifies the role of the local system in an APPN network for the remote controller being configured. This parameter is only used when the local system has enabled the branch extender function via the NODETYPE parameter in the network attributes being set to *BEXNODE.

Type
*CHAR
Required
No
Default
*NETNODE
Length
50
Case
Uppercase

Allowed values: *ENDNODE, *NETNODE

*NETNODE
The local system takes the role of a network node for the remote controller.
*ENDNODE
The local system takes the role of an end node for the remote controller.

HPRPTHSWT HPR path switching

Specifies whether an attempt is made to switch paths of HPR connections associated with this controller at the time the controller is varied off. If a path switch is not attempted or if there are no other available paths, jobs associated with the HPR connections will be ended. See the APPN information in the Networking category in the IBM i Information Center at http://www.ibm.com/systems/i/infocenter/ for more information.

Type
*CHAR
Required
No
Default
*NO
Length
50
Case
Uppercase

Allowed values: *NO, *YES

*NO
When this controller is varied off path switching will not be done for HPR connections associated with this controller. Jobs associated with HPR connections will be ended.
*YES
When this controller is varied off an attempt to switch paths of HPR connections associated with this controller will be made.

TMSGRPNBR APPN transmission group number

Specifies the transmission group number for this controller.

Type
*INT4
Required
No
Default
1
Range
1 to 20
Case
Uppercase

Suggested / special values: *CALC

1
The default transmission group is one.
*CALC
The system specifies the value for the transmission group number.
transmission-group-number
Specify a value from 1 to 20 for the transmission group number.

MINSWTSTS APPN minimum switched status

Specifies the minimum status of the switched connection so that APPN will consider it as a controller that is available for routing.

Type
*CHAR
Required
No
Default
*VRYONPND
Length
50
Case
Uppercase

Allowed values: *VRYON, *VRYONPND

*VRYONPND
APPN will consider the controller available for routing if the status is vary on pending, varied on, or active.
*VRYON
APPN will consider the controller available for routing only if the status is varied on or active.

AUTOCRTDEV Autocreate device

Specifies whether device descriptions can be automatically created for this controller description. Note: This parameter does not apply to the automatic creation of APPC devices. This parameter only applies to dependent devices on this controller.

Type
*CHAR
Required
No
Default
*ALL
Length
50
Case
Uppercase

Allowed values: *ALL, *NONE

*ALL
All dependent devices than can be automatically created for this controller, except APPC devices, are automatically created.
*NONE
Dependent devices on this controller are not automatically created.

AUTODLTDEV Autodelete device

Specifies the number of minutes an automatically created device can remain in an idle state (when there are no active conversations on that device). When the time expires, the system automatically varies off and deletes the device description.

Type
*INT4
Required
No
Default
31680
Range
1 to 31680
Case
Uppercase

Suggested / special values: *NO

31680
The system will automatically vary off and delete the automatically-configured idle device descriptions after 31680 minutes (22 days).
*NO
The system will not automatically vary off and delete the automatically-configured idle device descriptions.
1-31680
Specify the number of minutes to wait before deleting the automatically-configured idle device descriptions for this controller. Valid values range from 1 to 31680 minutes (22 days).

USRDFN1 User-defined 1

This field is used to describe unique characteristics of the line that you want to control. This parameter is valid only if advanced peer-to-peer networking (APPN) is used on the system.

Type
*INT4
Required
No
Default
*LIND
Range
0 to 255
Case
Uppercase

Suggested / special values: *LIND

*LIND
The user-defined value specified in the line description is used.
user-defined
Specify a value ranging from 0 through 255.

USRDFN2 User-defined 2

This field is used to describe unique characteristics of the line that you want to control. This parameter is valid only if advanced peer-to-peer networking (APPN) is used on the system.

Type
*INT4
Required
No
Default
*LIND
Range
0 to 255
Case
Uppercase

Suggested / special values: *LIND

*LIND
The user-defined value specified in the line description is used.
user-defined
Specify a value ranging from 0 through 255.

USRDFN3 User-defined 3

This field is used to describe unique characteristics of the line that you want to control. This parameter is valid only if advanced peer-to-peer networking (APPN) is used on the system.

Type
*INT4
Required
No
Default
*LIND
Range
0 to 255
Case
Uppercase

Suggested / special values: *LIND

*LIND
The user-defined value specified in the line description is used.
user-defined
Specify a value ranging from 0 through 255.

TEXT Text 'description'

Specifies the text that briefly describes the object.

Type
*CHAR
Required
No
Default
*BLANK
Length
50
Case
Uppercase

Suggested / special values: *BLANK

*BLANK
No text is specified.
character-value
Specify no more than 50 characters of text, enclosed in apostrophes.

DEV Attached devices

Specifies the names of the devices that are attached to this controller. The device descriptions must already exist. Up to 254 devices can be attached to this controller.

Type
*NAME
Required
No
Length
10
List limit
254
Case
Uppercase

CODE Character code

Specifies whether the extended binary-coded decimal interchange code (*EBCDIC) or the American National Standard Code for Information Interchange (*ASCII) character code is used on the line.

Type
*CHAR
Required
No
Default
*EBCDIC
Length
50
Case
Uppercase

Allowed values: *ASCII, *EBCDIC

*EBCDIC
The extended binary-coded decimal interchange code (EBCDIC) character code is used.
*ASCII
The ASCII character code is used.

SSCPID SSCP identifier

Specifies the system service control point identifier of the host system.

Type
*CHAR
Required
No
Length
50
Case
Uppercase
system-service-control-point-identifier
Specify the system service control point identifier as a 12-digit hexadecimal value.

SWTDSC Switched disconnect

Specifies whether the switched connection to this controller is dropped when the last device is varied off.

Type
*CHAR
Required
No
Default
*YES
Length
50
Case
Uppercase

Allowed values: *NO, *YES

*NO
The switched connection is not dropped when the last device is varied off.
*YES
The switched connection is varied off when the last device is varied off.

DSCTMR Disconnect timer

Specifies options for controlling the time (in seconds) before a connection without activity is dropped, or the amount of time to delay the automatic disconnection. If the user does not want the line to drop, specify *NO for the SWTDSC parameter.

Type
*ELEM
Required
No
Case
Uppercase
30
The disconnection is delayed for 30 seconds.
170
A connection is dropped when it has been inactive for 170 seconds.
disconnect-timer
Specify a time to wait before disconnecting. Valid values range from 0 through 65535 seconds.
disconnect-delay-timer
Specify a value to delay link take down after the last session on the controller is stopped. Valid values range from 0 through 65535 seconds.
Elements in order

Minimum connect timer Minimum connect timer

Type
*INT4
Required
No
Default
170
Range
0 to 65535
Case
Uppercase

Disconnection delay timer Disconnection delay timer

Type
*INT4
Required
No
Default
30
Range
0 to 65535
Case
Uppercase

CMNRCYLMT Recovery limits

Specifies the number of recovery attempts made by the system before an inquiry message is sent to the system operator. Also specifies the time (in minutes) that must elapse before the system sends an inquiry message to the system operator indicating that the recovery attempt count limit is reached. More information on communication recovery is in the Communcations Management book, SC41-5406.

Type
*ELEM
Required
No
Case
Uppercase

Suggested / special values: *SYSVAL

2
Two recovery attempts are made within the interval specified.
5
The specified number of recovery attempts is made within a 5-minute interval.
*SYSVAL
The value in the QCMNRCYLMT system value is used.
count limit
Specify the number of second-level recovery attempts to be made. Valid values range from 0 through 99.
time-interval
Specify the time interval (in minutes) at which the specified number of second-level recoveries are attempted. Valid values range from 0 through 120. If the value specified for count-limit is not 0, the value 0 specifies infinite recovery.
Elements in order

Count limit Count limit

Type
*INT4
Required
No
Default
2
Range
0 to 99
Case
Uppercase

Time interval Time interval

Type
*INT4
Required
No
Default
5
Range
0 to 120
Case
Uppercase

MSGQ Message queue

Specifies the message queue to which operational messages are sent. For more information about using this command, see the Communcations Management book, SC41-5406.

Type
*QUAL
Required
No
Default
*SYSVAL
Case
Uppercase

Suggested / special values: *SYSVAL, *SYSOPR

*SYSVAL
Messages are sent to the message queue defined in the QCFGMSGQ system value.
*SYSOPR
Messages are sent to the system operator message queue (QSYS/QSYSOPR).
name (Message queue)
Specify the name of the message queue to which operational messages are sent.
name (Library)
Specify the name of the library where the message queue is located.
Qualified parts (object, then library; write LIBRARY/OBJECT)

Part 37-01

Type
*NAME
Required
No
Length
10
Case
Uppercase

Part 37-11

Type
*NAME
Required
No
Length
10
Case
Uppercase

Suggested / special values: *LIBL, *CURLIB

AUT Authority

Specifies the authority you are giving to users who do not have specific authority for the object, who are not on an authorization list, and whose group profile or supplemental group profiles do not have specific authority for the object.

Type
*NAME
Required
No
Default
*CHANGE
Length
10
Case
Uppercase

Suggested / special values: *ALL, *CHANGE, *EXCLUDE, *LIBCRTAUT, *USE

*CHANGE
The user can perform all operations on the object except those limited to the owner or controlled by object existence (*OBJEXIST) and object management (*OBJMGT) authorities. The user can change and perform basic functions on the object. *CHANGE authority provides object operational (*OBJOPR) authority and all data authority. If the object is an authorization list, the user cannot add, change, or remove users.
*ALL
The user can perform all operations except those limited to the owner or controlled by authorization list management (*AUTLMGT) authority. The user can control the object's existence, specify the security for the object, change the object, and perform basic functions on the object. The user also can change ownership of the object.
*USE
The user can perform basic operations on the object, such as running a program or reading a file. The user cannot change the object. Use (*USE) authority provides object operational (*OBJOPR), read (*READ), and execute (*EXECUTE) authorities.
*EXCLUDE
The user cannot access the object.
*LIBCRTAUT
The system determines the authority for the object by using the value specified for the Create authority (CRTAUT) parameter on the Create Library (CRTLIB) command for the library containing the object to be created. If the value specified for the CRTAUT parameter is changed, the new value will not affect any existing objects.
name
Specify the name of an authorization list to be used for authority to the object. Users included in the authorization list are granted authority to the object as specified in the list. The authorization list must exist when the object is created.

Examples

CRTCTLAPPC CTLD(GRIFFIN) LINKTYPE(*HPRIP) RMTINTNETA('9.5.5.1') RMTCPNAME(CJP)

This command configures an APPC controller description named GRIFFIN with a link type of *HPRIP, a remote internet address of 9.5.5.1 and a remote control point of CJP.

IBM command documentation

Generated from os/cl/catalog/CRTCTLAPPC.json and os/cl/help/CRTCTLAPPC.json.