Command reference / comm

CRTCTLLWS

Create Controller Description (Local Work Station)

The Create Controller Description (Local Work Station) (CRTCTLLWS) command creates a controller description for a local work station controller. Note: Extended wireless controller configuration data is contained in the source file and member specified by the INZFILE and INZMBR parameters, respectively. When the controller is varied on, this configuration data is downloaded to the wireless adapter. It is recommended that INZPGM(QZXCINZ) and INZFILE(QEWCSRC) be used, and that a valid value be specified for the INZMBR parameter. For more information about downloading extended wireless controller configuration data, see the LAN, Frame-Relay and ATM Support book, SC41-5404 book. More information about using this command is in the Local Device Configuration book, SC41-5121 book.

Allowed environments: *ALL. Positional parameters: 4.

Restrictions

Parameters

CTLD Controller description

This is a required parameter. Specifies the name of the controller description.

Type
*NAME
Required
Yes
Length
10
Case
Uppercase

TYPE Controller type

This is a required parameter. Specifies the type of controller for this description.

Type
*CHAR
Required
Yes
Length
50
Case
Uppercase
2637
The ASCII local work station controller on a 9402 system.
2638
The twinaxial local work station controller on a 9402 system.
2661
The twinaxial local work station controller on a 9402 system.
2722
Local work station controller.
2746
Twinaxial work station controller.
2747
Twinaxial work station controller.
6040
The twinaxial local work station controller on a 9406 system.
6041
The ASCII local work station controller on a 9406 system.
6050
The twinaxial local work station controller on a 9402, 9404, or a 9406 system.
6054
The twinaxial local work station controller on a 9402, 9404, or a 9406 system.
6055
The twinaxial local work station controller on a 9402, 9404, or a 9406 system.
6056
The twinaxial local work station controller on a 9402, 9404, or a 9406 system.
6140
The twinaxial local work station controller on a 9404 system.
6141
The ASCII local work station controller on a 9404 system.
6180
Local work station controller.
9173
The LocalTalk work station adapter for the 9402-2xx system is used.
266A
The local work station controller for wireless devices is used.
266C
Local work station controller.
6A58
The local work station controller on a 9401, 9402, 9404, or 9406 system.
6A59
The local work station controller on a 9401, 9402, 9404, or 9406 system.
915A
The local work station controller for the 9406-3XX system is used.
916A
The local work station controller for the 9406-3XX system is used.

MODEL Controller model

This is a required parameter. Specifies the model of the work station controller. For controller types 6A58 and 6A59, model 0001 is for the local work station controller and model 0002 is for the operations console. All other controller types use only model 0001.

Type
*CHAR
Required
Yes
Length
50
Case
Uppercase

RSRCNAME Resource name

Specifies the resource name that identifies the hardware this description represents. Use the WRKHDWRSC command to determine the resource name. This is a required parameter.

Type
*NAME
Required
Yes
Length
10
Case
Uppercase

ONLINE Online at IPL

Specifies whether this object is automatically varied on at initial program load (IPL).

Type
*CHAR
Required
No
Default
*YES
Length
50
Case
Uppercase

Allowed values: *NO, *YES

*YES
The controller is automatically varied on at IPL.
*NO
The controller is not automatically varied on at IPL.

INZFILE Initialization source file

Specifies the NAME of a source file containing configuration initialization data. Note: The INZFILE and INZMBR parameters are required when downloading extended wireless controller configuration data to the wireless adapter as discussed at the beginning of this command description. The NAME of the initialization file NAME can be qualified by one of the following library values:

Type
*QUAL
Required
No
Case
Uppercase
*NONE
No initialization file name is specified.
*LIBL
All libraries in the library list for the current thread are searched until the first match is found.
*CURLIB
The current library for the job is searched. If no library is specified as the current library for the job, the QGPL library is used.
library-name
Specify the name of the library to be searched.
initialization-file-name
Specify the name of a source file containing the initialization data. A value of *NONE is accepted for this parameter. If a source file name has not been added prior to varying on this controller description then the current IOP defaults are used for initializaion.
Qualified parts (object, then library; write LIBRARY/OBJECT)

Part 5-01

Type
*NAME
Required
No
Length
10
Case
Uppercase

Part 5-11

Type
*NAME
Required
No
Length
10
Case
Uppercase

Suggested / special values: *LIBL, *CURLIB

INZMBR Initialization source member

Specifies the NAME of a source file member containing configuration initialization data (for a type 266A controller only). Note: The INZFILE and INZMBR parameters are required when downloading extended wireless controller configuration data to the wireless adapter as discussed at the beginning of this command description.

Type
*NAME
Required
No
Default
*NONE
Length
10
Case
Uppercase

Suggested / special values: *NONE

*NONE
No source file member is specified.
initialization-member-name
Specify the name of a source file member containing the initialization data. A value of *NONE is accepted for this parameter. If a source member name has not been added prior to varying on this controller description, then the current IOP defaults are used.

INZPGM Initialization program

Specifies the name of a program to manage configuration initialization data. Note: For 2663 wireless adapters, it is recommended that INZPGM(QZXCINZ) be specified. This results in the values of INZFILE and INZMBR being passed to the Change Extended Wireless Line Member (CHGEWLM) command when the line is varied on. The NAME of the initialization program NAME can be qualified by one of the following library values:

Type
*QUAL
Required
No
Case
Uppercase
*NONE
No initialization program name is specified.
*LIBL
All libraries in the library list for the current thread are searched until the first match is found.
*CURLIB
The current library for the job is searched. If no library is specified as the current library for the job, the QGPL library is used.
library-name
Specify the name of the library to be searched.
initialization-program-name
Specify the name of a program to manage configuration initialization data. If a program name is specified, it is called when this controller description is created. The name of the source file and member containing configuration initialization data are passed to this program as parameters.
Qualified parts (object, then library; write LIBRARY/OBJECT)

Part 7-01

Type
*NAME
Required
No
Length
10
Case
Uppercase

Part 7-11

Type
*NAME
Required
No
Length
10
Case
Uppercase

Suggested / special values: *LIBL, *CURLIB

TEXT Text 'description'

Specifies the text that briefly describes the object.

Type
*CHAR
Required
No
Default
*BLANK
Length
50
Case
Uppercase

Suggested / special values: *BLANK

*BLANK
No text is specified.
character-value
Specify no more than 50 characters of text, enclosed in apostrophes.

DEV Attached devices

Specifies the names of the devices that are attached to this controller. The device descriptions must already exist. The following list shows the maximum number of device descriptions that can be attached to each controller and the number of devices that can be active for each controller.

Type
*NAME
Required
No
Length
10
List limit
120
Case
Uppercase

DEVWAITTMR Device wait timer

Specifies the device wait timeout value. This is used to limit the amount of time that a subsystem takes for the work station input/output to complete. The timeout value that is used for each device is obtained from the controller that it is attached to at vary on time. A change in this parameter value takes effect for attached devices when they are next varied on. When selecting a value for this parameter, the types of devices attached to the controller should be taken into account. Locally attached work stations should have a low value for this parameter (10 seconds or less).

Type
*INT4
Required
No
Default
10
Range
2 to 600
Case
Uppercase
10
For local controllers, the subsystem waits a maximum of 10 seconds for the completion of the input/output of each work station attached to this controller.
device-wait-timer
Specify a value ranging from 2 through 600 that specifies the maximum number of seconds that the subsystem waits for work station input/output to complete for all work stations attached to this controller.

AUTOCFG Auto-configuration controller

Specifies whether this controller description is the one which should have devices attached when they are automatically configured. Although there can be more than one controller description for each controller, only one description can be an automatic configuration controller. When new devices are automatically configured on that controller, they are attached to the automatic configuration controller description.

Type
*CHAR
Required
No
Default
*NO
Length
50
Case
Uppercase

Allowed values: *NO, *YES

*NO
This is not an automatic configuration controller.
*YES
This is an automatic configuration controller.

AUT Authority

Specifies the authority you are giving to users who do not have specific authority for the object, who are not on an authorization list, and whose group profile or supplemental group profiles do not have specific authority for the object.

Type
*NAME
Required
No
Default
*CHANGE
Length
10
Case
Uppercase

Suggested / special values: *ALL, *CHANGE, *EXCLUDE, *LIBCRTAUT, *USE

*CHANGE
The user can perform all operations on the object except those limited to the owner or controlled by object existence (*OBJEXIST) and object management (*OBJMGT) authorities. The user can change and perform basic functions on the object. *CHANGE authority provides object operational (*OBJOPR) authority and all data authority. If the object is an authorization list, the user cannot add, change, or remove users.
*ALL
The user can perform all operations except those limited to the owner or controlled by authorization list management (*AUTLMGT) authority. The user can control the object's existence, specify the security for the object, change the object, and perform basic functions on the object. The user also can change ownership of the object.
*USE
The user can perform basic operations on the object, such as running a program or reading a file. The user cannot change the object. Use (*USE) authority provides object operational (*OBJOPR), read (*READ), and execute (*EXECUTE) authorities.
*EXCLUDE
The user cannot access the object.
*LIBCRTAUT
The system determines the authority for the object by using the value specified for the Create authority (CRTAUT) parameter on the Create Library (CRTLIB) command for the library containing the object to be created. If the value specified for the CRTAUT parameter is changed, the new value will not affect any existing objects.
name
Specify the name of an authorization list to be used for authority to the object. Users included in the authorization list are granted authority to the object as specified in the list. The authorization list must exist when the object is created.

MSGQ Message queue

Specifies the message queue to which operational messages are sent. For more information about using this command, see the Communcations Management book, SC41-5406.

Type
*QUAL
Required
No
Default
*SYSVAL
Case
Uppercase

Suggested / special values: *SYSVAL, *SYSOPR

*SYSVAL
Messages are sent to the message queue defined in the QCFGMSGQ system value.
*SYSOPR
Messages are sent to the system operator message queue (QSYS/QSYSOPR).
name (Message queue)
Specify the name of the message queue to which operational messages are sent.
name (Library)
Specify the name of the library where the message queue is located.
Qualified parts (object, then library; write LIBRARY/OBJECT)

Part 13-01

Type
*NAME
Required
No
Length
10
Case
Uppercase

Part 13-11

Type
*NAME
Required
No
Length
10
Case
Uppercase

Suggested / special values: *LIBL, *CURLIB

Examples

CRTCTLLWS CTLD(MYCTLR) TYPE(6050) MODEL(1) RSRCNAME(CTL02) INZFILE(*LIBL/MYFILE) INZMBR(MBR2)

This command creates a 6050 Model 1 local work station controller description with the name MYCTLR, and a resource name of CTL02. The source member MBR2, in source file MYFILE, will contain configuration initialization data.

IBM command documentation

Generated from os/cl/catalog/CRTCTLLWS.json and os/cl/help/CRTCTLLWS.json.